The Installation Requirements for Cryogenic Valves

Because of the special structure of cryogenic valves, the installation of cryogenic valves also has special requirements. The direction of the valve stem must be within a vertical angle of 45 degrees when the cryogenic valve is installed due to the structural characteristics of its long-neck bonnets, and installation on vertical pipelines should be avoided as much as possible. Otherwise, the low-temperature medium will fill the extended part of the valve bonnet, causing the valve...

The Installation Requirements for Cryogenic Valves Read More »

The Design of Petrochemical Cryogenic Valves (Part Two)

(2) The structure design of the dripping board Since the medium in the valve is a low-temperature medium, in order to avoid or reduce the transmission of the medium's temperature to the valve stem and the filling material at the upper end, and prevent these materials from failing due to freezing, a dripping plate can be added to the valve. Some research institutes have carried out experimental verification on this kind of valve with a drip plate, and proved that the upper...

The Design of Petrochemical Cryogenic Valves (Part Two) Read More »

The Design of Petrochemical Cryogenic Valves (Part One)

In recent decades, with the development of modern science and technology, there has been an increasing demand for cryogenic valves in engineering projects. Cryogenic valves are widely used in fertilizer, LNG and petrochemical fields and they are suitable for medium with temperatures between -40℃ and -250℃. Cryogenic valves include cryogenic ball valves, cryogenic solenoid valves, cryogenic gate valves, cryogenic globe valves, cryogenic safety valves, cryogenic check...

The Design of Petrochemical Cryogenic Valves (Part One) Read More »

The Analysis of Low-pressure Sealing of Swing Check Valves (Part Two)

3. Analysis of low-pressure sealing test standards for check valves 3.1 Requirements in the Chinese standard system In the current national standard system, the main regulations related to check valves include GB/T 13932-2016 Iron Swing Check Valves and GBT 13927-2008 Pressure Tests for Industrial Valves. GB/T 13932-2016 section 5.2 Pressure Test stipulates that the shell's strength test and sealing performance test of the check valve shall be carried out in accordance with the method...

The Analysis of Low-pressure Sealing of Swing Check Valves (Part Two) Read More »

The Analysis of Low-pressure Sealing of Swing Check Valves (Part One)

Abstract In industrial practice, the high-pressure sealing of swing check valves is generally guaranteed, but the low-pressure sealing is often overlooked, which may cause serious abnormal working conditions. The principle of low-pressure sealing of swing check valves, the reasons for low-pressure sealing being neglected, and the applicable standards of low-pressure sealing are discussed based on this to improve the reliability of low-pressure sealing of swing check valves.   Treatment of the...

The Analysis of Low-pressure Sealing of Swing Check Valves (Part One) Read More »

Repair Standards for Gate Valves

  1. The working principle and function of the gate valve Gate valves are cut-off valves used to cut off or connect the medium in the pipe, which are usually installed on pipes with a diameter greater than 100mm. The disc is shaped like a wedge. The gate valve has the advantages of easy opening and closing and low flow resistance. However, the sealing surface is easy to wear and leak; the opening stroke is great, and the maintenance is difficult. The gate valve cannot...

Repair Standards for Gate Valves Read More »

Maintenance and Quality Standards of Gate Valves

Maintenance and quality standards of gate valves are shown as follows: Items Parts for maintenance Key points of the process Quality requirements 1 Visual inspection of the valve body 1. Remove dirt and heat preservation. 2. Check the surface of the valve body for defects such as double skin, cracks, and sand holes. There are no double skin, cracks, and sand holes on the surface of the valve body.   2 Disassembly of valves 1. Keep a record before disassembly. 2. The...

Maintenance and Quality Standards of Gate Valves Read More »

Repair of Gate Valves

1. Disassembly of gate valves Remove the fixing bolts of the upper frame of the bonnet; unscrew the nuts of the four bolts on the bonnet and turn the stem nut counterclockwise to separate the valve frame from the valve body. Then use a lifting tool to lift the frame down to the right place. The stem nut is to be disassembled for inspection. Take out the retainer ring at the sealing part of the valve body, and press the bonnet with a special tool to make a...

Repair of Gate Valves Read More »

An Introduce to a Y-strainer

A Y-strainer is an indispensable filter device in the pipeline system for conveying the medium. A Y-strainer is usually installed at the inlet of a pressure reducing valve, a pressure relief valve, a level control valve, or other equipment to remove impurities in the medium, thus making valves and equipment used normally. A Y-strainer has the characteristics of advanced structure, small resistance, and convenient sewage discharge. The applicable media of a Y-strainer can be water, oil, and gas....

An Introduce to a Y-strainer Read More »

About us

We have a foundry and several machining centers. After more than 30 years of innovation and development, we have become a factory integrating design, research and development, manufacturing and sales. There are more than 500 employees, including nearly 200 workers for R&D and technology. We have a professional production workshop, a complete set of large-scale CNC machining centers, automated horizontal machining centers, large-scale gantry vertical lathes, automatic welding machines, and a complete production line.